Product Details:
Payment & Shipping Terms:
|
High Light: | multiparameter patient monitor,patient monitoring system,patient monitoring equipment |
---|
Portable Multi - parameter Patient Monitor with 7 - lead ECG Waveforms Display ETCO2
Descrition:
Portable Multiparameter Patient Monitor with ECG, RESP, NIBP, SpO2, TEMP, PR and ETCO2;
Optional with thermal recorder, IBP;
12.1 inch TFT screen;
Resolution ratio:800*600BMP;
luminance:300-350;
MEAS: 440*260*460mm/unit 520*440*470mm/2units;
Weight:9kg.
Applications:
Portable Multiparameter Patient Monitor apply to ICU, CCU, operation, adult, pediatrics and neonatal patient
Specifications:
Portable Multiparameter Patient Monitor:
● Standard parameter: ECG, RESP, NIBP, SpO2, TEMP, PR and ETCO2.
● 12.1" large-screen color TFT display
● 7-lead ECG waveforms display ,big font observational interface
● Reviewable ECG waveforms, Maximum 72 hours reviewing graphic trends
● Digital SpO2 technique, precise measurement for weak perfusion and finger shaking
● Arrhythmia and S-T segment analysis and pacemaker detection
● Protection against interference from defibrillation and electrosurgical Unit
● Adjustable 3 level audio and visual alarm
● Applicable to ICU, CCU, operation, adult, pediatrics and neonatal patient
● Built-in high-capacity battery, Battery-low indicator
● Optional with thermal recorder, IBP
Competitive Advantage:
We provide the whole life time guarantee for inside boards of patient monitor, except man-made damage or burnt then can't be repaired.
ECG
Lead mode:3-lead or 5-lead
Lead selection:I;II;III,avR;avF;V
Heart rate range:Adult:15-300bpm;Pediatric/Neonatal:15-300bpm
ECG waveform:2 channals
Accuracy: ±1 bpm or ±1%,which is greater
S-T segment detection;measurement range: -2.0mv~2.0mv
Alarm:Yes,audible and visual alarm,alarm events review
NIBP
Method:Oscillometry
Modes:Manual/Auto/Comtinuous
Auto measure time:Adjustable
Measurement range:10-270mmHg
SPO2
Measurement range:0-100%
Accuracy:70-100%,±2%,0-69%,upspecified
Auto measure time:Adjustable
Pulse Rate
Range:20-254bpm
Accuracy: ±3bpm
Respiration
Method:RA-LL impedance
Range:Adult:0-120rpm;pediatric/neonatal:0-150rpm
Apnca alarm:Yes
Temperature
Range: 0 ~ 50 °C
Accuracy: ± 0.10
Channal:Dual-channel
ETCO2 concentration
Measure range: 0-99 mmHg
Accuracy: ±2mmHg, when CO2 concentration is in 0-5.0%,
no larger than ±6% of the readings, when CO2 concentration is >5.0%
Standard Accessories:
Neonatal / Package Type SPO2 Probe:
Printer, ETCO2 optional:
Packing:
Contact Person: Ms. christina xia
Fax: 86-10