12 Lead 12 Channel Digital ECG Machine with Interpretive 5 , 10 , 20 mm / mV
Functions:
◆ Twelve Channel digital ECG machine with Interpretive.
◆ Simultaneous 12 lead acquisition, 12-channel, 6-channel printing form at choice. Date, time and parameters, including paper speed, heart rate, sensitivity, filter status, and etc. print out.
◆ Designed with a high-resolution thermal printer to print out ECG waveform, annotation as well as related parameters for diagnosis reference.
◆ Recording paper for ECG-912 is 210mm in width.
◆ Simultaneous 12 lead acquisition.
◆ Visual display of operation menu, ECG waveform and parameters.
◆ Digital isolation technology is adopted to minimize time/temperature drift of components so as to promote adaptability of the unit to circumstance.
◆ Digital filter for effective inhibition of baseline drift, interference, as well as automatic position of baseline.
◆ Self-test upon powering on.
◆ Function of rhythm lead for observing abnormal ECG waveform & heart rate.
◆ Automatic measurement and interpretation of ECG waveform to relieve doctors from strain.
◆ Multiple print formats include 6-channe and 12-channel.
◆ AC/Rechargeable battery for continuous examination when AC power supply is unavailable. For battery operation, ECG-912 is equipped with a charger & system for battery capacity management and protection itself from excessive discharge.
◆ Safety level for ECG-912corresponds to Class I, type CF.
specifications:
Lead |
Standard 12 leads |
Input Circuit |
Isolated input circuit Protection against defibrillation and pace making |
Data Acquisition |
Simultaneously 12 lead acquisition |
Calibration Voltage |
1mV±5% |
Sampling Rate |
1ms |
A/D Converter |
12 bit |
Print Format |
Automatic/Manual: 6 channel, 12 channel Neutral value + Rhythm lead |
Operation Mode |
AUTO: Automatic lead change; Automatic measurement and interpretation |
MAN: Manual lead change |
|
Parameter Measurement |
Ventricle heart rate; P-R interval; QRS duration; QT/QTC interval; P/QRS/T axis; RV5/SV1 amplitude |
Filter |
AC filter, EMG filter, DFT filter |
CMRR |
>60dB >100dB (AC filter in use) |
Input Circuit Current |
≤0.1mA |
Input Impedance |
>50MW |
Patient Leakage Current <10mA |
|
Time Constant |
≥3.2s |
Frequency Response |
0.05 ~ 100Hz |
Noise Level |
<15mVp-p |
Threshold |
≤20mV |
Skin Voltage Tolerance |
±300mV |
Sensitivity |
5, 10, 20mm/mV |
Baseline Control Dimensions of Packing |
Automatic baseline control Automatic inhibition of baseline drift |
Dimensions |
400mm*325mm*84.5mm |
Dimension of Packing |
510mm*430mm*230mm |
N,W |
6kg |
G.W |
8kg |
Environment Conditions |
Transportation |
Storage |
Operation |
Temperature: |
-40℃~+55℃ |
-10℃~+40℃ |
+5℃~+40℃ |
Relative Humidity: |
25%~95%(Non condensed) |
25%~80% |
25%~80% |
Atmospheric Pressure: |
700hPa~1060hPa |
700hPa~1060hPa |
860hPa~1060hPa |
Accessories:
1.Patient cable…………………1 PC
2.Limb electrode………………………4 PCS
3.50mm X 20m roll ECG paper………1 Roll
4.Three plugged power cable…………1 PC
5.Chest electrode……………………6 PCS
6.Backup AC fuse……………………2 PCS
7.Operating instructions……………1 Copy
8.Earth connecting line……………1 PC
9.Certificate……………… ………1 Copy